Spectrophotometer
Each category provides detailed information about our products, their applications, and benefits, empowering you to select the equipment that best suits your research goals.
Each category provides detailed information about our products, their applications, and benefits, empowering you to select the equipment that best suits your research goals.
Wavelength Range:190 to 900 nm
Wavelength Accuracy:£ ±0.5 nm
Wavelength Repeatability:£ 0.3 nm (single direction)
Spectrum Bandwidth:0.2 nm, 0.4 nm, 0.7nm, 1.4 nm, 2.4 nm, 5.0 nm
Wavelength range :190 to 900 nm
Spectral bandwidth:0.1, 0.2, 0.4, 1.0 and 2.0 nm
Accuracy of the wavelength:±0.15 nm
Receptivity of the wavelength :≤0.04 nm
Spectrum Bandwidth:2 nm
Wavelength Range:190 to 1100 nm
Monochromatic Type:Czerny-Turner
Grating:1600 lines/mm
Spectrum Bandwidth:0.5 nm, 1nm, 2 nm, 4 nm, 5 nm
Wavelength Range:190 to 1100 nm
Monochromatic Type:Czerny-Turner
Grating:1600 lines/mm
Monochromatic type:Czerny turner
Focal length:160 mm
Wavelength Range:190 to 1100 nm
Band Width:1.8 nm
Monochromatic type:Czerny turner
Focal length:160 mm
Wavelength Range:190 to 1100nm
Band Width:2 nm
Exciting Optical Filters:Interface optical filter (10 nm bandwidth)
Wavelength:365 nm
Emission Monochromatic:C-T diffraction grating (EM 200 to 900 nm )
Wavelength Accuracy:±1 nm
Light Path:1mm
sample Volume:1 to 2μL
Detection Range:190 to 850 nm
Wavelength Range:190 to 1100 nm
Optical Path:1/0.5/0.05 mm automatic conversion
Optical Range:190 to 1100 nm
Sample Volume:0.3 to 2.0 μl
Light Source:Long-life Xenon lamp
Wavelength scanning Range:190 to 850 nm
Wavelength Accuracy:±1 nm
Optical Path:1/0.5/0.05 mm automatic conversion
Optical Range:190 to 1100 nm
Wavelength Range:190 to 850 nm
Wavelength Accuracy:± 1 nm
Wavelength Resolution:2 nm (FWHM at Hg 546 nm)
Repeatability:<± 0.5 nm
Wavelength Range:190 to 850 nm
Wavelength Accuracy:± 1nm
Wavelength Resolution:2 nm (FWHM at Hg 546 nm)
Repeatability:<± 0.5 nm
Wavelength Range:900 to 1700 nm
Wavelength Accuracy:±1 nm
Wavelength Reproducibility :≤1 nm
Wavelength Scanning Interval Absorbance:1 nm, 4 nm, 8 nm, 16 nm
Photometry:Split Beam
Monochromatic Type:Czerny-Turner
Focal Length:160 mm
Grating:1200 lines/mm
Photometry:Split Beam
Monochromatic Type:Czerny-Turner
Focal Length:160 mm
Grating:1200 lines/mm
Photometry:Split Beam
Monochromatic Type:Czerny-Turner
Focal Length:160 mm
Grating:1200 lines/mm
Photometry:Split Beam
Monochromatic Type:Czerny-Turner
Focal Length:160 mm
Grating:1200 lines/mm
Photometry:Single Beam
Monochromatic Type:Czerny-Turner
Focal Length:160 mm
Grating:1200 lines/mm
Photometry:Single Beam
Monochromatic Type:Czerny-Turner
Focal Length:160 mm
Grating:1200 lines/mm
Photometry:Single Beam
Monochromatic Type:Czerny-Turner
Focal Length:160 mm
Grating:1200 lines/mm
Photometry:Single Beam
Monochromatic Type:Czerny-Turner
Focal Length:160 mm
Grating:1200 lines/mm
Photometry:Single beam
Monochromatic Type:Littrow
Focal Length:160 mm
Wavelength Setting:Manual Turn Knob
Analysis Principle:Energy-dispersive X-ray fluorescence analysis
Element Measuring Range:Any element from Na(11)-U(92)
Minimum Measuring Limit:Cd/Hg/Br/Cr/Pb≤2 ppm
Sample Shape:Arbitrary size, any irregular shape